Silica analyzer 5500sc, 1 measuring channel, with reagents
Overview
Use only 2 liters of assorted reagents to perform continuous analysis for up to 90 days; Double that of the Silica series 5000 analyzer.
As an analyzer that uses a pressure compression system to dispense reagents, there is no need for an internal pump, minimizing maintenance needs.
Diagnostic tools including Hach’s exclusive Prognosys Technology, warning LEDs, and clear message display allow you to avoid unplanned downtime.
No more problems with reagents getting spilled in the equipment, the floor or on your clothes while fumbling with tubes and straws. With the improved design, now you just need to gently rotate the cap and straw into the sealed bottle containing the reagent to match the colors.
The input and output raw sampling feature allows rapid analysis of a sample poured into the analyzer and facilitates sampling from the analyzer for revalidation by laboratory testing.
Product information
Accuracy:
0–500 µg/L: ±1% or ±1 µg/L of reading, whichever is higher
500–5000 µg/L: ±5%
Alarm: 4 relays output; type: not powered SPDT relays, rated 5 A resistive, 240 VAC,maximum
Connector: 18 to 14 AWG wire, 18 AWG stranded recommended
Certification: CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000 ) KC (EN 61326-1: 2006) C-tick (EN 61326-1: 2006) cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012)
Controller compatibility: sc200, sc1000
Dimensions (H x W x D):31.7 in x 17.8 in x 14.2 in (804 mm x 452 mm x 360 mm)
Protection level: NEMA 4X/IP56
Flow rate: sample inlet and bypass: 6 mm (¼-in.)
Air inlet: 6 mm (¼-in.)
Chemical drain hole and case: 9.5 mm (3/8-in.)
Raw sampling: incoming and outgoing samples
Light source: Class 1M LED (light emitting diode) with 810 nm peak
Low level detection limit (LOD): 0.5 µg/L
Measuring principle: color comparison
Number of measurement channels: 1, 2, 4, 6; get sequentially
Operating humidity: 5 to 95 % zero dew point (indoor use only)
Operating temperature: 5 to 45 °C (41 – 113 °F)
Output signal: 4 – 20 mA
Pollution level: 2/II
Power requirement (Hz):50/60 Hz; (Voltage):100 – 240 V AC
Protection level: I
Measurement range: 0.5 to 5000 µg/L as SiO 2
Chemical consumption: 2 L of each reagent for 90 days with 15 minute measurement interval
Repeatability: ± 0.5 µg/L or ± 1 % of reading, whichever is greater
Response time: typical, 9.5 minutes at 25 °C (77 °F); change with temperature
Sample flow rate: 55 to 300 mL/min
Sample Pressure: 2 to 87 psi (Preset Pressure Regulator)
Sample temperature: 5 to 50 °C (41 – 122 °F)
Storage conditions: -20 to 60 °C (-4 – 140 °F)
Warranty: 2 years
Weight: 44.09 lbs. (20 kg) (45 lb) without reagents and standards, 36.3 kg (80 lb) with reagents.